RF Communications

Connectors: Main line ‘N’ Female. Coupled line ‘BNC’ Female
Coupling Ratio: -30 dB +/- 0.5 dB
Forward/Reverse Discrimination: >30 dB
Frequency: 2 – 50MHz Full specification*
Insertion Loss: <0.1 dB
Max VSWR: 2.5: 1
Notes: N.B. at 1kW the forward output signal is 1 Watt. *The coupler is effective over a very much wider frequency range with a small degradation in performance. Calibration charts can be supplied for those out of band frequencies, where for example, measurement of harmonics is desired.
Power Rating: 1kW continuous. 2.5kW peak
Return Loss (Matched Load): 26.5 dB
Connectors: Main line 1 7/8″. Coupled line – ‘N’ female
Coupling Ratio: -26 dB +/- 0.5 dB
Forward/Reverse Discrimination: >30 dB
Frequency: 2 – 32MHz Full specification*
Insertion Loss: <0.1 dB
Max VSWR: 2.5: 1
Notes: At 30kW the forward output signal is 75 Watt. *The coupler is effective over a very much wider frequency range with a small degradation in performance. Calibration charts can be supplied for those out of band frequencies, where for example, measurement of harmonics is desired.
Power Rating: 30kW continuous and peak
Return Loss (Matched Load): 26.5 dB
Connectors: Main line 1 5/8″. Coupled line – ‘N’ female
Coupling Ratio: -26 dB +/- 0.5 dB
Forward/Reverse Discrimination: >30 dB
Frequency: 2 – 32MHz Full specification*
Insertion Loss: <0.1 dB
Max VSWR: 2.5: 1
Notes: N.B. at 30kW the forward output signal is 75 Watts. The coupler is effective over a very much wider frequency range with a small degradation in performance. Calibration charts can be supplied for those out of band frequencies, where for example, measurement of harmonics is desired.
Power Rating: 30kW continuous and peak
Return Loss (Matched Load): 26.5 dB